GD6900 Capacitance and Dissipation Factor Tester
GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.
-
GDBT-10000kVA/36kV Advanced Transformer Test System for Comprehensive Diagnostics
GDBT-10000kVA/36kV is mainly to make no-load and load test, power frequency withstand voltage test, induction withstand voltage test, temperature rising test, DC resistance test and ratio test for 36kV, 10000kVA and below distribution transformers.
-
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.
-
GDB-P Auto Transformer Turns Ratio Tester
According to IEC and the relevant national standards, transformer turns ratio test is a necessary project in the process of power transformer production, user handover and maintenance test.
-
GDZRC Series DC Winding Resistance Tester (GDZRC-10A)
GDZRC-10A
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment. -
GDZRC-10U DC Winding Resistance Tester
The measurement of DC transformer resistance is a mandatory test item in transformer manufacturing of semi-finished products, finished products factory test, installation, handover test and preventive test of power department, which can effectively find the manufacturing defects of transformer coil material selection, welding, loose connection parts, missing strands, broken wires and other hidden dangers after operation.
GDZRC-10U DC Winding resistance tester is a rapid test equipment for measuring the DC resistance of transformers, transformers, generators and motors, and it is a replacement product of single and double arm Bridges.
-
GDOT-80A Insulation Oil Tester
Please read the operation manual carefully before operating.
Please check if the tester is well connected to earth before testing.
It is forbidden to move or lift the testing cover in the process of testing to avoid injury by high voltage. Power must be off before replace sampling oil. -
GDRB-B Transformer Frequency Response Analyzer
Power transformer winding deformation tester (frequency response method) is based on the measurement of characteristic parameters of transformer internal windings, adopts the internal fault frequency response analysis (FRA) method, can accurately judge the internal faults of transformers.
-
GDZRC-10H Hand-held Transformer DC Winding Resistance Tester
GDZRC-10H Hand-held Transformer DC Winding Resistance Tester is not only suitable for the measurement of inductive test object such as transformer, CT/PT and reactor, but also for the measurement of resistive test object such as copper bar, wire and switch contact
As a newly-designed product, it has features of small size, fast test speed and high accuracy. -
GDZRS-20B Three Phase DC Winding Resistance Tester
GDZRS-20B Three Phase DC Winding Resistance Tester is a new generation of rapid tester that integrates magnetization method testing, three-phase testing (Yn, Y, △) and degaussing functions. It is an ideal equipment for measuring the DC resistance of large power transformers. The screen adopts a large-screen high-resolution LCD, which is convenient for on-site use. All direct resistance test items can be completed with one connection. The test speed is fast, the accuracy is high, and the measuring range is wide.
-
GDOT-80C Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation.
-
GDRB-C Power Transformer Winding Deformation Tester
Power transformer winding deformation tester (frequency response method) is based on the measurement of characteristic parameters of transformer internal windings, adopts the internal fault frequency response analysis (FRA) method, can accurately judge the internal faults of transformers.