Switch-gear Test Equipment

  • HCB-14  Circuit Breaker Analyzer

    HCB-14 Circuit Breaker Analyzer

    HCB-14 Circuit Breaker Analyzer  is widely applicable to mechanical characteristics testing scenarios for various types of high-voltage switchgear, including vacuum switches, SF6 switches, and oil switches. It meets the testing needs of power system switchgear in various scenarios, including factory inspection, operation and maintenance testing, overhaul and commissioning, and scientific research testing, providing professional data support for the safe and stable operation of switchgear.

  • GDSL-A-5000A/10V    Single Phase Primary Current Injection Test  Set

    GDSL-A-5000A/10V Single Phase Primary Current Injection Test Set

    GDSL-A-5000A/10V  Single Phase Primary Current Injection Test  Set uses a PLC and a 19-inch industrial tablet computer as its control system, enabling both manual and automatic temperature rise testing. This test device can output a single-phase current of 5000A and collect data from 16 temperature sensors. It displays the collected temperature and current data in the form of graphs and can export the data as a CSV file for easy analysis and processing on a computer. The device also features comprehensive protection measures.

  • HPCI SER. Primary Current Injection Test Set

    HPCI SER. Primary Current Injection Test Set

    HPCI SER. Primary Current Injection Test Set uses digital control technology, with strong anti-interference ability.It features a low-power, high-capacity auto-coupled voltage regulator and a current transformer built with a high-permeability iron core, resulting in high output power, compact size, and light weight. It is mainly used for primary busbar protection and various current transformer ratio tests, and is widely used in scientific research, production, and electrical testing at power, railway, petrochemical, metallurgical, and mining companies.

  • GDKC-15D  Circuit Breaker Analyzer

    GDKC-15D Circuit Breaker Analyzer

    High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15D circuit breaker analyzer is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. 

  • GDSL-D-5000A/6V Primary Current Injection Test Set

    GDSL-D-5000A/6V Primary Current Injection Test Set

     Primary Current Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy to use and maintenance. 

  • GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

    GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

    GDSL-A Series 3-phase Primary Current Injection Test Set with Temperature Test is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy use and maintenance.

     

     

     

     

     

  • GDKC-15A Circuit Breaker Analyzer

    GDKC-15A Circuit Breaker Analyzer

    High voltage circuit breaker is one of the most important control equipment in the power system.

    GDKC-15A circuit breaker analyzer is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate with high accuracy. 

     

     

     

  • GDSL-D Series Digital Primary Current Injection Test Set

    GDSL-D Series Digital Primary Current Injection Test Set

    GDSL-D series primary current injection test set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy use and maintenance.

  • GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer

    GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer

    High voltage circuit breaker is one of the most important control equipment in the power system.

     

  • GDSL-BX-100 Primary Current Injection Test Set

    GDSL-BX-100 Primary Current Injection Test Set

    GDSL-BX-100 Primary Current Injection Test Set, is mainly used for testing current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc.

  • GMDL-02A HV Circuit Breaker Analog Device

    GMDL-02A HV Circuit Breaker Analog Device

    GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. 

  • GDZK-IV Vacuum Degree Tester for Vacuum Breaker

    GDZK-IV Vacuum Degree Tester for Vacuum Breaker

    GDZK-IV is designed to measure the vacuum degree of vacuum breakers. It uses an electromagnetic discharge measuring method, to ensure the testing results accurate and reliable.The testing data can estimate vacuum breaker’s health and life span.

12 Next > >> Page 1 / 2