GDHG-201P CT/PT Analyzer

GDHG-201P CT/PT Analyzer

Brief Description:

GDHG-201P CT/PT Analyzer is a lightweight, portable unit capable of testing both current and voltage transformers.

  • CT testing includes Excitation Characteristic Test, Knee Points, Turn Ratio, Polarity, Secondary Winding Resistances, Secondary Burden,Ratio Error, Angular Difference
  • VT testing including Excitation Characteristic Test, Knee Points, Turn Ratio, Polarity, Secondary Winding Resistances, Ratio Error, Angular Difference

 

 

 


Product Detail

Product Tags

Features

Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT.
Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of transformers.
Accurately measure the ratio error and angular difference, the maximum allowable error of the ratio error is ±0.05%, and the maximum allowable error of the angular difference is ±2min. It can measure the 0.2S level current transformer, and the ratio measurement range is 1~40000.
Based on the advanced frequency conversion method to test CT/PT voltage-current characteristic curve and 10% error curve, the maximum AC voltage of 180V and AC current of 12Arms (36A peak) can be output, but it can deal with the CT test of knee point up to 60KV.
Auto test CT/PT parameters such as knee point voltage/current, 5% and 10% error curve, accuracy limit factor (ALF), safety factor (FS), secondary time constants (Ts), magnetic remanence coefficient (Kr), saturated and unsaturated inductance.
The test meets various types of transformer standards such as GB1208 (IEC60044-1), GB16847 (IEC60044-6), and GB1207, and tests standards are automatically selected according to the type and level of the transformer.
The test is simple and convenient. CT DC resistance, excitation, ratio and polarity can be completed by one key. Besides burden test, all other tests of CT adopt the same wiring mode.
5.7-inch graphic transflective LCD, clearly visible in the sun.
Operated with a rotating optical mouse, the operation is simple, fast and convenient, and easy to master.
Built-in printer, automatically prints the generated test report.
The test results can be exported by U disk, and the program can be upgraded with U disk, which is convenient and quick.
Save 1000 groups data and it is not lost after power down.
It is equipped with background analysis software to facilitate the storage, conversion and analysis of test reports, and can be used for comparison, judgment and evaluation of test data.
Easy to carry, device weight < 10kg.

Specifications
Model GDHG-201P
Application CT, PT
Output 0~180Vrms, 12Arms, 36A(Peak Value)
Voltage Measuring Precision ±0.1%
CT Turns Ratio Test Range 1~40000
Precision ±0.05%
PT Turns Ratio Test Range 1~40000
Precision ±0.05%
Phase Test Range ±2 min
Precision 0.5 min
Secondary winding resistance Test Range 0~30
Precision 0.22
AC burden Test Range 0~1000VA
Precision 0.20.02VA
Input voltage AC220V±10%, 50Hz
Working environmental Temperature: -10℃~50℃, Humidity: ≤90%
Dimension & Weight 365*290*153mm, 10kg
Accessories
Host 1 piece
Power cord 1 piece
Red test cable 1 piece
Yellow test cable 1 piece
Green test cable 1 piece
Ground cable 1 piece
Alligator clip (Jaw 12mm) 4 pieces
Alligator clip (Jaw 20mm) 2 pieces
Inserting piece 4 pieces
Print paper 4 rolls
disk 1 piece
Fuse 10A 5 pieces
Special screwdriver for fuse 1 piece
Users guide 1 copy
Warranty period 1 copy
Packing list 1 copy
Factory test report 1 copy